Testing of Biomarine CCR 1000 Closed Circuit U.B.A.

Show full item record


Title: Testing of Biomarine CCR 1000 Closed Circuit U.B.A.
Author: Cetta, TW; Radecki, R
Abstract: Breathing resistance and CO2 scrubber duration tests were performed. The maximum breathing resistance measured at 198 FSW during a breathing rate of 30 breaths per minute with a 2.0 Liter Tidal Volume breathing through a Mk VI mouth-piece was -15 centimeters of H2O during inhale and +14.5 centimeters of H2O during exhale. The CO2 scrubber duration was determined under three conditions at 200 FSW 32 degree F water with 0.85 SLPM CO2 add rate with a duration of 2 hours 40 minutes; 32 degree F water with a 1.2 SLPM CO2 add rate and a duration of 1 hour 57 minutes; and finally in 72 degree F H2O with a 0.85 SLPM CO2 add rate and a duration of 7 hours, 10 minutes.
Description: Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested.
URI: http://archive.rubicon-foundation.org/4778
Date: 1975