Miscellaneous Considerations Regarding Closed Circuit Oxygen Scuba.

Rubicon Research Repository/Manakin Repository

Miscellaneous Considerations Regarding Closed Circuit Oxygen Scuba.

Show simple item record


dc.contributor NAVY EXPERIMENTAL DIVING UNIT WASHINGTON D C en_US
dc.contributor.author Leyden, CJ en_US
dc.contributor.author Searle, WF, Jr en_US
dc.contributor.author Zamperini, AL en_US
dc.date.accessioned 2006-08-30T03:13:10Z
dc.date.available 2006-08-30T03:13:10Z
dc.date.issued 1959 en_US
dc.identifier.govdoc AD0781258 en_US
dc.identifier.govdoc NEDU-Evaluation-25-59 en_US
dc.identifier.other *Closed circuit oxygen scuba, en_US
dc.identifier.uri http://archive.rubicon-foundation.org/3335
dc.description Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. en_US
dc.description.abstract The status of several closed circuit oxygen scuba is reviewed and recommendations for future developments are made. The German Drager and the USN Mark 3 are discussed in some detail and the USN Mark 4 is briefly described. Further improvements of the Mark 3 are enumerated and continued development is recommended, concurrently with development of the wholly new Mark 4 unit. A brief review of early closed circuit oxygen scuba is included along with an anotated bibliography of previous reports pertinent to this type breathing apparatus. (Author) en_US
dc.format.extent 7443638 bytes
dc.format.mimetype application/pdf
dc.language.iso en_US
dc.rights Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: Unclassified; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested. en_US
dc.subject Diver equipment en_US
dc.subject Scuba diving en_US
dc.subject Reviews en_US
dc.subject Regulators en_US
dc.subject Valves en_US
dc.title Miscellaneous Considerations Regarding Closed Circuit Oxygen Scuba. en_US

Files in this item

Files Size Format View
NEDU_1959_25.pdf 7.098Mb PDF View/Open

This item appears in the following Collection(s)