COMPUTATION OF HELIUM-OXYGEN DECOMPRESSION TABLES.

Show full item record


Title: COMPUTATION OF HELIUM-OXYGEN DECOMPRESSION TABLES.
Author: Molumphy, GG
Abstract: The tables are computed to the nearest foot - less than 0.5 is dropped, 0.5 or more is considered an additional foot. When computing the time of the final stop, any fraction of a minute is considered an additional minute. At stops other than the final stops, the saturation loss of the controlling tissue governs. Whether or not to consider a fraction of a minute must be determined by inspection. This last step is necessary because tissue loss is rounded off to the nearest foot.
Description: Citation Status: Active; Citation Classification: Unclassified; Title Classification: Unclassified; Report Classification: Unclassified; Identifier Classification: None; Abstract Classification: Unclassified; Distribution Limitation(s): 01 - APPROVED FOR PUBLIC RELEASE; Information provided by the Department of Defense and the Defense Technical Information Center (http://www.dtic.mil/) is considered public information and may be distributed or copied unless otherwise specified. Use of appropriate byline/photo/image credits is requested.
URI: http://archive.rubicon-foundation.org/3319
Date: 1950

Files in this item

Files Size Format View
NEDU_1950_07.pdf 3.955Mb PDF View/Open

This item appears in the following Collection(s)

Show full item record